Field-verified facts entered after site checks and document review: profiles, external environment, separation distances, policies, plans, training, inspections and response staffing.
Industry framework briefing · Updated
In one sentence: Before a building can carry a fire-prevention capability index, somebody has to produce its data - the shared data layer that lets buildings, platforms and assessors speak one language about fire safety.
At a glance
Platform scores diverge for one reason: the inputs are not the same. A shared collection framework makes the inputs identical, so any compliant platform computing the same fields reaches comparable results.
The reference framework fixes the collection scope before any scoring is discussed. Each row below is a family of fields with a declared primary source; profiles feed every later judgement, including whether a protection system is even required.
| Group | Size | Covers | Primary source |
|---|---|---|---|
| Fire safety management | 5 duties | Safety policy and archives, emergency and evacuation plans, training and drills, daily and periodic inspection, on-site response capability | Manual |
| Common - building profile | 16 fields | Type, nature, height, storeys above and below grade, total and footprint area, volume, largest single floor, hazard class, seat and bed counts, central air conditioning, fire-resistance level, construction date, use type | Manual |
| Building fire prevention | 13 items | External environment, fire lanes, separation distances, fire resistance, height and storey type, building age, compartments, egress, layout, occupant density, interior linings, insulation, electrical equipment | Manual / AI |
| Fire protection systems | 7 systems | Outdoor and indoor hydrants, automatic alarm, automatic sprinklers, smoke control and exhaust, extinguishers and other means, maintenance regime | Manual / IoT |
Every field carries a declared source type, and the mix matters: data completeness, value density and the manual / IoT / AI ratio are themselves evaluation dimensions in the downstream program.
Field-verified facts entered after site checks and document review: profiles, external environment, separation distances, policies, plans, training, inspections and response staffing.
Live facility status reported by connected sensors: electrical load and detection results, hydrant pressure, alarm and sprinkler health, online status and long-unresolved faults.
Image and video recognition where it is reliable: lane and egress obstruction monitoring, reading combustion-performance grades of linings and insulation, with human review of results.
The boundary is explicit: people submit raw fields; judgement is computed. This is what keeps two platforms from reaching two different truths from the same building.
Answers draw on one shared dictionary so values compare across platforms and years. Samples:
| Enumeration | Values |
|---|---|
| Fire hazard class | Class A / B / C / D / E (Jia-Yi-Bing-Ding-Wu) |
| Storey type | Single-storey / multi-storey / high-rise / underground |
| Structure type | Reinforced concrete / frame / steel structure / temporary |
| Fire-resistance level | Level 1 / Level 2 / Level 3 / Level 4 / below Level 4 |
| Combustion performance | A / B1 / B2 / B3 |
The IoT-sourced fields are only as real as the devices behind them. The mappings below show published Wanlin device families against the framework fields they feed; model selection always follows the site survey.
| Framework field | Device family | What it proves |
|---|---|---|
| Protection-system status (hydrant, sprinkler, tank) | WANLIN-770 4G pressure gauges, WANLIN-780 4G level gauges | Mains pressure and tank levels reported live instead of graded from an annual reading |
| Electrical load and detection (indicator 1.13) | Smart electricity set: host 705 with breakers 710 / 711 | Design versus measured load and electrical fault detection at distribution boxes |
| Alarm system networking (indicator 2.3) | WANLIN-921 user information transmission | Networks an existing fire alarm panel; online and linkage status supervised (GB 26875.3) |
| Detection coverage in corridors, sheds and homes | WANLIN-307 / 309 / 310 smoke, WANLIN-340 heat | Battery-powered points whose installed-and-online state is itself verifiable data |
| Maintenance evidence (indicator 2.7) | Cloud maintenance tickets and patrol records | Faults, repairs and monthly upkeep leave timestamped records rather than claims |
Conditional fields such as seat count or bed count are left empty when not applicable; whether a protection system is required is judged from the building profile rather than assumed.
Inventory what already exists - drawings, records, live devices - map it to the field list, then close the gaps: manual items first, IoT coverage where continuous monitoring pays back.
Three source types are declared per field: manual entry after site checks, IoT devices reporting live facility status, and AI-assisted recognition such as lane monitoring and material-grade reading, with human review of AI results.
GB/T 41020-2021, the national guideline for fire risk assessment of building property insurance, is the declared minimum granularity for the collection items.
Yes. Fire-resistance levels, combustion-performance classes, hazard classes, building classifications and structure types all draw on one shared enumeration dictionary, so values are comparable across platforms.
Collect once, use everywhere: the same profile fields drive compliance grading, system-requirement judgement and the capability index. That reuse is the business case for doing the collection layer properly.
Scope disclosure: this page explains a published industry data framework in plain terms for fire-safety practitioners; it is educational and does not assert any participation status, designation or certification for Wanlin products. Program participation, assessments and certificate scope must be confirmed through the organizing bodies and, for devices, against the exact model and configuration. To discuss how your building data could meet the framework, contact wanlinfirecontrol@163.com or 4006-016-119 / +86 132 6167 7119.
Conditional fields such as seat count or bed count are left empty when not applicable; whether a protection system is required is judged from the building profile rather than assumed.
Inventory what already exists - drawings, records, live devices - map it to the field list, then close the gaps: manual items first, IoT coverage where continuous monitoring pays back.
Three source types are declared per field: manual entry after site checks, IoT devices reporting live facility status, and AI-assisted recognition such as lane monitoring and material-grade reading, with human review of AI results.